Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. I used electrical tape so the impeller Power is always present at supply input. Nothing seems to give it juice. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. "caption": "In The Swim Blog"
During that time, the pump got really hot and melted the fitting on the top. Capacitor is a battery in the back of the motor, at 9 oclock that assists in starting the motor, if the capacitor was weak, that may draw more amps from the breaker. Also check other possible pressure side problems, like a closed or broken exit valve on the filter, or other restrictions further down the line, up to the pool return fittings. Hayward should be able to help, http://www.haywardnet.com see for contact info. Not sure what would cause that?!? . WTF! 1. It may not display this or other websites correctly. If it is new, you may have undersized the cell, or your water chemistry is imbalanced, preventing the chlorine from working efficiently and effectively. Hi Bobby, so you have power at the motor, but no noise. When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. Not sure what to call it voltage selector perhaps? could be cord problem, too. Any ideas how to address this? All works good now. If so, the issue would reoccur again, after vacuuming usually. Thats good such frozen motors are common in the spring. Does it mean the problem is on the pump itself ? Weve not had this issue the past 2 years (we bought the house 2 years ago). I have backwashed the filter and the water is clear. hayward super pump C48L2N134B1. Automatic reset is immediate after error is corrected. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Hi, when my Hayward pool heater is on Im getting a sour odour from the exhaust. After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. Hi, open up the air bleeder on the filter when you open the pump to release the vacuum seal from pump to filter. If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. IF that all looks good, consider replacing the capacitor. Hi my spa empties into the pool when the spa is turned on. The pump acts like it wants to pump, but doesnt. Entire pump system with pump basket and housing. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. It can also happen when voltage is incorrect (too high or too low), or when wires are shorting out, or in some cases, very hot weather and direct sunshine and other nearby sources of heat. Next step would be to remove the cover and put your leads on the terminal board, right where each wire connects. Recently I started getting a loud vibration hum from my hayward pump. Hi Douglas, it could be the capacitor, if youre lucky. However, no matter what. The capacitor is at 9 oclock and the thermal regulator at 12 oclock. No lights are coming on as if no power. Chapter 1: The Evil Emperor's Son. When I turn the switch on for the pool, the breaker flips immediately. Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. You might be surprised by how many people neglect to check this area. We believe it needs a new seal. It sounds more like a filter problem, one that might be fixed by using a good pool filter cleaner, or you may need new filter media. Hi Keri, I understand, with Hayward Valves, incl the most common top mounted sand filter valve SP0714T, have the Spider Gasket molded to the underside of the rotor. It is usually set to run at high rpm early morning and that is before sun hits it. I have a Hayward SP2607x10 pump with a Hayward C48k2n143B1 self priming super pump. My pool suppoier said 50lb but the info on the description of the filter on the site where purchased says 100 lbs. If that doesnt solve the problem, then work through the steps below. Be sure the wiring is tight on both ends. Basically it ran normal and then would get loud, and then go back to normal. I turned it on and it ran fine for about one hour. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. But the clicking, that sounds like a centrifugal switch, on the rear of the shaft, which could be a voltage issue? It happens every time. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. it runs How To Identify The Problem Look at all the metal components in and around your swimming pool. Flex pipe used on skimmers can eventually narrow and crimp, leaving a small opening that clogs easily. View Details Usfitnessfinder.com. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. How did it end up? Good news.not really. Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). Thoughts? 1. I replaced the motor a couple of years ago. Hi Mary, pump motors have a thermal overload switch, which trips when motor gets too hot, it resets itself when the motor cools down, and the motor should restart again on its own. You can either take the motor to an electric motor repair shop for rebuilding (new seals/bearings), or buy a new motor, or buy a new pump. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Most likely, and unfortunately yes. Before you purchase a new Hayward pool pump, its important to verify that the pump is the right size for your pool piping. }
. The plastic shroud or cover over the impeller? Thanks. Mine just did the same. Never had an issue with the other motors we have had. I changed the sand and it is still occurring. Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. Chlorinator Pro CP-15 Cell. Hi, make sure that the switches are not loose, the centrifugal switch on the end of the shaft and the Stationary switch at 6 oclock. Probably not cant think of another issue. Hi Doug, my first guess would be that the motor was set to accept 230V but was given 115V, or vice versa. At75%, or lower, in either polarity, it's time to consider replacing the cell. Sometimes you can reposition it, or reglue it, or make it work for a little while longer, while you order the correct spider gasket to match your make/model of valve. Thank you! If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings.
Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP - Pool Supply Unlimited Please advise ). If you dont have a control system, and just a breaker box subpanel and maybe a time clock, the click could be coming from a switch inside the motor, which could be loose wires, low power, bad capacitor, loose switch, or something jamming up the motor shaft or internal fan. Sean, Hi Sean, no worries. Hi, my Hayward pump is about 5 years old. I have cleaned the rubber gasket, made sure the springs touch to no avail. "datePublished": "3/27/2015",
Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I put new sand it its still dumping could it have been sand still in the line what you think or is there anything else that could cause this I put 200 lbs of sand in which is the correct amount . Any suggestions? If it is not, re-align your flow switch. Im having a problem with my super pump. I would turn it off and it would hum and eventually start. Ive had the pool for 25 years with no problems until now. Contains 13 high-performance titanium electrode plates that are coated with a special formula that combines the most corrosion-resistant metal on earth, iridium and ruthenium, to ensure extended cell life and increased chlorine production efficiency. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! It could also be a loose switch in the back of the motor. If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. I will re-check all the wiring. I have a Hayward Super II pump that has had a small leak between the pump housing and seal plate. Then I saw a HS code. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. Shouldnt be having a problem so soon, no but it can happen, but more likely to not be the shaft seal, but the exit pipe, or a leak around the impeller housing, check the bolts around the pump, to be sure they are tight. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Im not sure what happened. All breakers have some wiggle to them usually, but a very loose breaker could be a hazard for arcing or even fire so should be checked out, if so. I had it replaced. I took apart the impeller and didnt see anything that could cause a problem. Sounds like a leak from the shaft seal, although it could be dripping from the pipe carrying water out of the pump, running down and dripping off the bottom. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. In such case, filter pressure is lower than normal, if the impeller is clogged. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. Check the pump lid o-ring or gasket, and be sure the lid is very tight. When I go to backwash the filter pump shuts down. Also, because of this leak, would It cause my pressure to decrease? Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. Specialties: Cycling, Kickboxing, The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. I opened my pool this weekend and started the pump and let it run for few hours before stopping it. Loose wire connections or touching terminal connections cause sparking. Do you have any tips? 7 yrs old and used year round. We purchased a Hayward Pump SP3220EE and I need to know how After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. Any suggestions? In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Any thoughts? that sounds like loose wires, or broken wires. Fault with the pump wiring. PUMP IS 15 YEARS OLD. Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. Hi James, for a two speed motor, I would suggest the run capacitor, but not sure if the VS motor has one? This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. I never had this problem before. What would have caused this? Its a Hayward self-priming Super Pump. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. This year, I have replaced all the plumbing from the pump to the filer. The loose wire you found in the pump, that was a good catch, there should be no hanging wires in the rear of the motor, all wires from the terminal board, to the switches and capacitor should be tightly connected, and the metals ends should never touch any other metal parts, except the terminal they connect to Retrace your steps to recheck power to the motor. Anyway, have you checked the cleaner line strainer? Would this make the breaker flip? to turn off the timer. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Hi George, that is a strange one, because you dont backwash, yet pressure returns to normal, just by shutting pump off for a minute, then restarting? One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. I am very sure the water comes from underneath, not from plumbing fitting threads. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Any thoughts? Hi Davy. Flush out the housing to clear debris, then refill with water. You can also pressurize the suction lines using a Drain King, connected to a garden hose and inserted at the skimmer, with a plug inside of the pump on the incoming pipe, or setting the multiport valve on closed. "keywords": "",
Hi! otherwise all else seems to read ok. Id check the cell number just to confirm it is the TCELL15. This is more of an indicator light than anything else. Per your article, it sounds like I need a new capacitor. thanks. If the switch does not close after the blower starts the control will go into lockout with the blower running. Hi Leah, good question, and I understand. the , . Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. Reprime the pump again, open water valves and test. Or, 2). Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. I believe you must have some type of switch, for code cant just wire it directly to the breaker. 2. Gauge was reading between 6 and 8 on filter container at this time. Dont feel that resistance when bumping. The breaker on the panel tripped. Could need cleaning. Similar pumps, with the same flow rate characteristics, are not less expensive. Fitness View More.
Salt Chlorinator Problems - Repair or Replace? - InTheSwim Pool Blog This is actually the second motor in 6 months. Check for power with a multimeter, at the timeclock and at the pump motor terminal board. Was working fine until I backwashed and cleaned the basket by the pump. Any insight? Ran it for two hours, then shut it down to move valve to backwash. Display seems to be reading correctly and shows the cell is not generating. If it is not, re-align your flow switch. If it continues, a new o-ring might be the ticket, yes. Hi John hot plug? Please help! 5.
Pool360 - Blue-essence-20 20k Gal Salt Chlorination System - Poolcorp goes on first, then the spring, then the slightly larger hole washer. Next, maintain the proper salt levelin the pool. that would be rare, very rare. Hi Davy! Go to the grocery store and come back and its dead. Do I have a problem? If the flow is normal however, it could be a bad flow switch or pressure switch. Hello. Is there a thicker housing oring that could be installed to fix the leak? We are out of ideas and no one can solve this. 908-355-7995. Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. If you find out, I would check the owners manual for information related to your symptoms. I have no pressure on my filter. Although in low speed, chlorine is not generated so not sure why even run the low speed. Im still getting air? In my area, the pool gets opened mid May and closed mid September, and runs around 8 hours a day. I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. "@type": "ImageObject",
Ray1davis@comcast .net. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. It leaks from the impeler case and is noisey, so assy B is no replacement. Anything else to fiddle with or bad motor? "height": "219",
I have an inground salt water pool with a spa and my flow rate was low so I cleaned out everything and replaced the filters and now the flow rate seems good with one problem. Then you can pump out the water with a submersible pump, or depending on the surface material and design of your water feature, it may be better for the surfaces not to drain it, but to treat it with chemicals and put a heavy cover over it, where possible. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. 2. check the pump motor wiring, at the timeclock and the motor. I will also say that a truly drip-proof pool system is not really the norm, most filter systems with a few years on it will ooze and drip here and there, and most often its of little concern. Is it problem of filter ? Any suggestions?? I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. Ok I switched out the capacitor and it started up and ran for about 5 second and then blew the capacitor. Please help! I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. power to my pool pump & timer quit working at the same time.
Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. "@type": "ImageObject",
It appeared that I couldve pulled them right off if I tried. Do you have any idea what I need to do to remedy the problem. 6. Sanitization, Learn About It makes humming sound 1-2 times before starting. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. I dont see that code listed. Or a loose base part rattling? runs normal on 110 but does not make any sound when set on 230 and wired accordingly. Motor is connected to 220 volts and each phase consume 3.8 amps. I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. A wire connected to the terminal board may be loose or burnt. Check the incoming voltage to be sure that you are within the range of 110V-125V. Why would this suddenly happen? The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself. bought a SP2610x152s super pool pump 1.5 hp. If I let it sit I can turn it on again, but just for about 20 seconds. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? Oh, and prepare yourself, a new motor or pump may be needed soon. Just opening pool. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). please update your current version of Internet Explorer or try using a different browser. Thanks for the reply! It is a generic Hayward pump with 1 HP. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. Learn more about pool care and repair. Hi John, if the outlet is GFCI, check the TEST button, it may have tripped. No matter what setting I put it in its backwashing the sand into the skimmer.